{id=392322734526, createdAt=1791968526154, updatedAt=1791968903194, 4='{type=image, value=Image{width=1457,height=650,url='https://www.latham-australia.com/hubfs/Mechanical%20Expansion%20Joint%20Covers/Seismic/1457x650-3D-Seismic%20Series%20FRLSM-100%20to%20FRLSM-600.jpg',altText='1457x650-3D-Seismic Series FRLSM-100 to FRLSM-600',fileId=392215592379}}', 1='{type=string, value=FRLSM-100 to FRLSM-600}', 3='{type=list, value=[{id=387347606007, name='Aluminium'}]}'}
Enquire about this product
Seismic Series - Extreme Movement - Floor, Wall & Roof

FRLSM-100 to FRLSM-600

Roof‑to‑Parapet Expansion Joint Cover

The FRLSM Seismic Series expansion joint covers are for roof-to-parapet installation on a hob, designed to combine with the roof sheet membrane which runs up the side of the expansion joint. The series comes standard with a BFG Water gutter. Splice plates can be supplied where cover plates are abutted, to ensure water tightness. 

 As standard the material is supplied in mill finish aluminium. On request, Latham can have the material powder coated or anodised to a required colour.

Materials

  • Aluminium 6063-T5 mill finish alloy.

  • Spring steel treated centring bar with nylon spherical balls at ~475mm centres.

  • Supplied in 3050mm lengths.

Fixings

  • Side members factory drilled with 10mm holes at ~475mm centres.

  • Wall member factory drilled to accept 8mm fixings at ~475mm centres.

  • Membrane hold-down clips are supplied for installation at ~500mm centres.

  • End Closures, Transition Splices, Corners and Tee’s should be considered for roof joints.

  • Contact a Latham representative for more information.

Why you should choose Latham products

TECHNICAL CHARACTERISTICS Illustrated: FRLSM-100
Aluminium Code A B Movement Total Available Movement
FRLSM-100 100 233 +100/-75mm 175mm
FRLSM-150 150 333 +150/-125mm 275mm
FRLSM-200 200 433 +200/-175mm 375mm
FRLSM-250 250 533 +250/-225mm 475mm
FRLSM-300 300 633 +300/-275mm 575mm
FRLSM-400 400 833 +400/-375mm 775mm
FRLSM-500 500 1033 +500/-475mm 975mm
FRLSM-600 600 1233 +600/-575mm 1175mm