{id=387726842359, createdAt=1791095531697, updatedAt=1791095552121, 4='{type=image, value=Image{width=1457,height=650,url='https://www.latham-australia.com/hubfs/Mechanical%20Expansion%20Joint%20Covers/Heavy%20Duty/1457x650-3D-Heavy%20Duty%20HHSL%E2%80%9025%20to%20HHSL%E2%80%90200.jpg',altText='1457x650-3D-Heavy Duty HHSL‐25 to HHSL‐200',fileId=387730961896}}', 1='{type=string, value=HHSL‑25 to HHSL‑200}', 3='{type=list, value=[{id=384446755269, name='Stainless Steel'}]}'}
Enquire about this product
Heavy Duty Series

HHSL‑25 to HHSL‑200

Floor‑to‑Wall Expansion Joint Cover with Stainless Steel Deck

The HHSL Series Heavy-Duty Pedestrian expansion joint covers with stainless steel cover plates are designed for heavy-duty pedestrian applications where floor-to-wall expansion joints are required. These are designed to work with the HHS Series floor expansion joint covers. They can accept heavier traffic (subject to the load and the span) such as EWP’s. For more load information, contact Latham Australia who can supply point loads to suit various traffic loads and wheel sizes. For regular vehicular traffic, the HDS or EHDF Series should be considered.

Materials

  • Aluminim 6063-T5 mill finish alloy.

  • 304 Grade 2B finish stainless steel cover plates to 6mm thickness, and #1 finish for cover plates thicker than 6mm.

  • Supplied in 3050mm lengths.

Fixings

  • Side members factory drilled to accept 8mm countersunk head fixings at ~350mm centres.

Why you should choose Latham products

TECHNICAL CHARACTERISTICS Illustrated: HHSL-50
Stainless Steel Code Smooth Deck A B C D E F Movement Total Available Movement Overall Depth Cover Plate Thickness
HHSL-25 25 75 57 18 12 50 +/-13mm 26mm 67mm 5mm
HHSL-50 50 100 82 18 12 50 +/-13mm 26mm 67mm 5mm
HHSL-75 75 125 107 18 12 50 +/-13mm 26mm 67mm 5mm
HHSL-100 100 150 132 18 12 50 +/-13mm 26mm 68mm 6mm
HHSL-150 150 200 182 18 12 50 +/-13mm 26mm 68mm 6mm
HHSL-200 200 250 232 18 12 50 +/-13mm 26mm 69mm 7mm
Special Note

Customers with special applications are invited to discuss them with us. Service factors must be taken into consideration when selecting tactile indicator studs or directional bars.

Have a question about your upcoming project or requirements?