{id=392745982445, createdAt=1792026708123, updatedAt=1792031667841, 4='{type=image, value=Image{width=1457,height=650,url='https://www.latham-australia.com/hubfs/Mechanical%20Expansion%20Joint%20Covers/Light%20Duty/1457x650-Tech%20Drawing-Light%20Duty%20Type%2050-WR%20&%20Type%2050%E2%80%90WCR.jpg',altText='1457x650-Tech Drawing-Light Duty Type 50-WR & Type 50‐WCR',fileId=392268284350}}', 1='{type=string, value=Type 50-WR & Type 50‑WCR Aluminium}', 3='{type=list, value=[{id=387347606007, name='Aluminium'}]}'}
Enquire about this product
Light Duty 50 Series

Type 50-WR & Type 50‑WCR Aluminium

Floor & Floor‑to‑Wall Expansion Joint Covers

Application

  • Surface mounted expansion joint covers should be laid on a bedding compound such as Latham Tytred 2, or glued down with Latham Titazel Thixotropic Epoxy Resin Adhesive, both in conjunction with stainless steel screws and plastic plugs or mechanical fixings.

  • Internal light duty, moderate traffic applications only, where limited movement is expected.

  • The 50-Series joint covers 
 allow a maximum of ±5mm of horizontal movement.

  • The 50-Series offers the opportunity to use the most similar joint cover in the wall and ceiling to the floor. This is particularly effective when the construction joint forms a square box shape. See FDR and FDRW Series

Materials

  • Aluminium 6063-T5 mill finish alloy.

  • Supplied in 4000mm lengths.

  • Standard replaceable synthetic rubber inserts are grey (beige or black can be supplied on request).

Fixings

  • Side members factory drilling available on request.

  • Wall members factory drilling available on request.

Why you should choose Latham products

TECHNICAL CHARACTERISTICS Factory drilling available on request
Aluminium Code A B C D E F G Movement Total Available Movement Overall Depth
50-WR 50 48 42 115 3 n/a 20 +/-5mm 10mm 23mm
50-WCR 50 45 42 85 3 38 20 +/-5mm 10mm 41mm
Special Note

Customers with special applications are invited to discuss them with us. Service factors must be taken into consideration when selecting tactile indicator studs or directional bars.

Have a question about your upcoming project or requirements?

form-bg.jpg